Infoseite // Dimmer for Arri Junior lamps



Frage von nahmo:


Hi,

would like to shoot various Arri Junior (150, 650, 1000 Watt) operate with dimmers. About possible changes to the color temperature I am aware.
Do I have otherwise as bezgl flicker or worse (voltage (Swandle) on / in the lamp itself) anything to look or can I simply plug in between ¬ 9.95 Konrad dimmer?

Can anyone help?

Thanks and regards,

nahmo

Space


Antwort von Mink:

http://www.thomann.de/de/stairville_ns_2002_handdimmer_2000w_indu.htm

I find this in order ...

Space


Antwort von nahmo:

Thanks for the answer, but what does that mean? That a favorable 0815-lamp dimmer does not work? Due to the high voltage lamps, because of wrong voltage? What requirements must have the dimmer?

Electricians have clearly manageable idea. Maybe you can help me or anyone else a little more detail?

Thanks,

nahmo

Space


Antwort von Markus_Krippner:

The dimmer is shown above the "official" solution. Will recommend you to everyone. Me too.

If you have decent lights (as Arri) have, I would therefore systematically synonymous relied on ordinary accessories.

If you'd buy 500 NEN Benz. yes you do not synonymous on it for cost reasons, the rims of precious old Golf. ;-)


... Mark :-)

Space


Antwort von Kino:

For a small premium's are the "Four Salvation" here:

http://www.thomann.de/de/showtec_multidim_local_controldmx.htm

Space


Antwort von chris_d:

"Markus_Krippner" wrote: The dimmer is shown above the "official" solution.

hi markus.
Do you know if this man with dimmer of stairville synonymous Kinoflo 4ft can dim 4banks?
likely to be released but the dim violet-something, right?

thanks, chris

Space


Antwort von hofnarr:

"Nahmo" wrote: What requirements must have the dimmer?
The dimmer must be at least the connected lamp power can cope with. Cheap electric power or dimmer for the living area are usually only up to 300 watt load.

I also recommend the above linked ns2002 (or his brother for purely resistive loads ns2003). good quality, have existed for decades.

http://www.fg-elektronik.de/fileadmin/user_upload/FG-Elektronik/ Standard / ac-ac/dimmer/Datenblatt_NS_2000_deutsch.pdf

for burner up to 800w, you can use synonymous FG002N the kemo, must be if favorable.

http://www.kemo-electronic.de/datasheets/fg002n.pdf

Space


Antwort von Markus_Krippner:

Hi Chris,

Fluorescent tubes as KinoFlo can with such a (phase control) dimmers NOT be dimmed. Phase control dimmer for incandescent own safety.

For dimming of fluorescent tubes special electronic ballasts are required. This is a completely different technology.

... Mark :-)

Space


Antwort von chris_d:

"Markus_Krippner" wrote: Hi Chris,

Fluorescent tubes as KinoFlo can with such a (phase control) dimmers NOT be dimmed.

For dimming of fluorescent tubes special electronic ballasts are required.

... Mark :-)


ok, thank you